paper

Design and Fabrication of a Highly Integrated Silicon Detector for the STAR Experiment at Brookhaven National Laboratory

arXiv:1404.0993

Abstract

We present the design of a detector used as a particle tracking device in the STAR experiment at the RHIC collider of Brookhaven National Laboratories. The "stave," 24 of which make up the completed detector, is a highly mechanically integrated design comprised of 6 custom silicon sensors mounted on a Kapton substrate. 4608 wire bonds connect these sensors to 36 analog front-end chips which are mounted on the same substrate. Power and signal connectivity from the hybrid to the front-end chips is provided by wire bonds. The entire circuit is mounted on a carbon fiber base co-cured to the Kapton substrate. We present the unique design challenges for this detector and some novel techniques for overcoming them.

14 Pages, 17 Figures. Submitted to New England iMAPS 2014 Symposium and Expo

Design and Fabrication of a Highly Integrated Silicon Detector for the STAR Experiment at Brookhaven National Laboratory · wovepaper