A 33 year constancy of the X-ray coronae of AR Lac and eclipse diagnosis of scale height
arXiv:1401.7346 · doi:10.1088/0004-637X/783/1/2
Abstract
Extensive X-ray and extreme ultraviolet (EUV) photometric observations of the eclipsing RS CVn system AR Lac were obtained over the years 1997 to 2013 with the Chandra X-ray Observatory Extreme Ultraviolet Explorer. During primary eclipse, HRC count rates decrease by ~40%. A similar minimum is seen during one primary eclipse observed by EUVE but not in others owing to intrinsic source variability. Little evidence for secondary eclipses is present in either the X-ray or EUV data, reminiscent of earlier X-ray and EUV observations. Primary eclipses allow us to estimate the extent of a spherically symmetric corona on the primary G star of about 1.3Rsun, or 0.86Rstar, and indicate the G star is likely brighter than the K component by a factor of 2-5. Brightness changes not attributable to eclipses appear to be dominated by stochastic variability and are generally non-repeating. X-ray and EUV light curves cannot therefore be reliably used to reconstruct the spatial distribution of emission assuming only eclipses and rotational modulation are at work. Moderate flaring is observed, where count rates increase by up to a factor of three above quiescence. Combined with older ASCA, Einstein, EXOSAT, ROSAT and Beppo-SAX observations, the data show that the level of quiescent coronal emission at X-ray wavelengths has remained remarkably constant over 33 years, with no sign of variation due to magnetic cycles. Variations in base level X-ray emission seen by Chandra over 13 years are only ~10%, while variations back to pioneering Einstein observations in 1980 amount to a maximum of 45% and more typically about 15%.
To appear in the Astrophysical Journal
References in corpus (6)
- X-ray Variability in the Young Massive Triple theta2 Ori A
- On X-ray Optical Depth in the Coronae of Active Stars
- X-ray activity cycle on the active ultra-fast rotator AB Dor A? Implication of correlated coronal and photometric variability
- Geometry Diagnostics of a Stellar Flare from Fluorescent X-rays
- Fe K alpha and hydrodynamic loop model diagnostics for a large flare on II Peg
- Eclipsed X-ray flares in binary stars: geometrical constraints on the flare's location and size
Cited by in corpus (14)
- Discriminating the Progenitor Type of Supernova Remnants with Iron K-Shell Emission
- Optical, UV, and X-Ray Evidence for a 7-Year Stellar Cycle in Proxima Centauri
- Stellar Activity and Coronal Heating: an overview of recent results
- MuSCAT2 multicolour validation of TESS candidates: an ultra-short-period substellar object around an M dwarf
- A Solar cycle correlation of coronal element abundances in Sun-as-a-star observations
- The RS CVn type star GT Mus shows most energetic X-ray flares throughout the 2010s
- Extending the FIP bias sample to magnetically active stars. Challenging the FIP bias paradigm?
- Giant coronal loops dominate the quiescent X-ray emission in rapidly rotating M stars
- Detection of Extremely Broad Water Emission from the molecular cloud interacting Supernova Remnant G349.7+0.2
- An X-ray study of coronally connected active eclipsing binaries
- Long-term variations in the X-ray activity of HR 1099
- Time-lapse Very Long Baseline Interferometry Imaging of the Close Active Binary HR 1099
- X-ray emission in the enigmatic CVSO 30 system
- X-raying the coronae of HD~155555