First data from DM-Ice17
arXiv:1401.4804 · doi:10.1103/PhysRevD.90.092005
Abstract
We report the first analysis of background data from DM-Ice17, a direct-detection dark matter experiment consisting of 17 kg of NaI(Tl) target material. It was codeployed with IceCube 2457 m deep in the South Pole glacial ice in December 2010 and is the first such detector operating in the Southern Hemisphere. The background rate in the 6.5 - 8.0 keVee region is measured to be 7.9 +/- 0.4 counts/day/keV/kg. This is consistent with the expected background from the detector assemblies with negligible contributions from the surrounding ice. The successful deployment and operation of DM-Ice17 establishes the South Pole ice as a viable location for future underground, low-background experiments in the Southern Hemisphere. The detector assembly and deployment are described here, as well as the analysis of the DM-Ice17 backgrounds based on data from the first two years of operation after commissioning, July 2011 - June 2013.
arXiv commentmatches PRD published version
References in corpus (49)
- Planck 2013 results. XVI. Cosmological parameters
- Particle Dark Matter: Evidence, Candidates and Constraints
- First results from the LUX dark matter experiment at the Sanford Underground Research Facility
- Dark Matter Results from 225 Live Days of XENON100 Data
- First results from DAMA/LIBRA and the combined results with DAMA/NaI
- Inelastic Dark Matter
- Dark Matter Results from 100 Live Days of XENON100 Data
- Results from 730 kg days of the CRESST-II Dark Matter Search
- Final model independent result of DAMA/LIBRA-phase1
- Search for Low-Mass WIMPs with SuperCDMS
- A search for light dark matter in XENON10 data
- Results from a Low-Energy Analysis of the CDMS II Germanium Data
- First Year Performance of The IceCube Neutrino Telescope
- The IceCube Data Acquisition System: Signal Capture, Digitization, and Timestamping
- CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors
- The DAMA/LIBRA apparatus
- The Design and Performance of IceCube DeepCore
- First dark matter search results from a 4-kg CFI bubble chamber operated in a deep underground site
- Final Analysis and Results of the Phase II SIMPLE Dark Matter Search
- Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
- Constraints on Low-Mass WIMP Interactions on 19F from PICASSO
- Dark Matter particles in the galactic halo: results and implications from DAMA/NaI
- Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes
- New Limits on Interactions between Weakly Interacting Massive Particles and Nucleons Obtained with CsI(Tl) Crystal Detectors
- Integrating Out Astrophysical Uncertainties
- Compatibility of DAMA Dark Matter Detection with Other Searches
- A Consistent Dark Matter Interpretation For CoGeNT and DAMA/LIBRA
- Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two Liter CFI Bubble Chamber
- Momentum Dependent Dark Matter Scattering
- Limits on WIMP cross-sections from the NAIAD experiment at the Boulby Underground Laboratory
- Dark Light Higgs
- Improved Spin Dependent Limits from the PICASSO Dark Matter Search Experiment
- Effect of Gravitational Focusing on Annual Modulation in Dark-Matter Direct-Detection Experiments
- The NAIAD experiment for WIMP searches at Boulby mine and recent results
- Limits on the spin-dependent WIMP-nucleon cross-sections from the first science run of the ZEPLIN-III experiment
- ACTIVIA: Calculation of Isotope Production Cross-sections and Yields
- Fitting the annual modulation in DAMA with neutrons from muons and neutrinos
- Search for An Annual Modulation in Three Years of CoGeNT Dark Matter Detector Data
- Light Dark Matter Anomalies After LUX
- Non-proportional scintillation response of NaI:Tl to low energy X-ray photons and electrons
- Particle Physics Implications for CoGeNT, DAMA, and Fermi
- CoGeNT, DAMA, and Light Neutralino Dark Matter
- Preliminary results of ANAIS-25
- A Search for the Dark Matter Annual Modulation in South Pole Ice
- Slow scintillation time constants in NaI(Tl) for different interacting particles
- A testable conventional hypothesis for the DAMA-LIBRA annual modulation
- DAMA vs. the annually modulated muon background
- Study of scintillation in natural and synthetic quartz and methacrylate
- Cosmic-ray physics with IceCube
Cited by in corpus (29)
- Dark matter direct-detection experiments
- Initial Performance of the COSINE-100 Experiment
- First search for a dark matter annual modulation signal with NaI(Tl) in the Southern Hemisphere by DM-Ice17
- Background model for the NaI(Tl) crystals in COSINE-100
- Annual Modulation in Direct Dark Matter Searches
- Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold
- Model-independent comparison of annual modulation and total rate with direct detection experiments
- Cosmogenic radionuclide production in NaI(Tl) crystals
- The COSINE-100 Data Acquisition System
- Assessment of backgrounds of the ANAIS experiment for dark matter direct detection
- Muon detector for the COSINE-100 experiment
- Understanding NaI(Tl) crystal background for dark matter searches
- The Past and Future of Light Dark Matter Direct Detection
- Dark matter search project PICO-LON
- Performance of a prototype active veto system using liquid scintillator for a dark matter search experiment
- Growth of Ultra-high Purity NaI(Tl) Crystal for Dark Matter Searches
- Radioactive contamination of scintillators
- A CsI low temperature detector for dark matter search
- Light yield determination in large sodium iodide detectors applied in the search for dark matter
- Bulk NaI(Tl) scintillation low energy events selection with the ANAIS-0 module
- Measurement of Muon Annual Modulation and Muon-Induced Phosphorescence in NaI(Tl) Crystals with DM-Ice17
- Particle detection at cryogenic temperatures with undoped CsI
- COSINE-100 and DAMA/LIBRA-phase2 in WIMP effective models
- Sensitivity of alkali halide scintillating calorimeters with particle identification to investigate the DAMA dark matter detection claim
- High purity NaI(Tl) scintillator to search for dark matter
- Current status and projected sensitivity of COSINE-100
- Measurement of low-energy background events due to Rn contamination on the surface of a NaI(Tl) crystal
- Composite dark matter and direct-search experiments
- Comparison of DAMA/LIBRA and DM ICE Results using Information Theory to Rule out Dark Matter Claims