Shielded button electrodes for time-resolved measurements of electron cloud buildup
arXiv:1311.7103 · doi:10.1016/j.nima.2014.02.047
Abstract
We report on the design, deployment and signal analysis for shielded button electrodes sensitive to electron cloud buildup at the Cornell Electron Storage Ring. These simple detectors, derived from a beam-position monitor electrode design, have provided detailed information on the physical processes underlying the local production and lifetime of electron densities in the storage ring. Digitizing oscilloscopes are used to record electron fluxes incident on the vacuum chamber wall in 1024 time steps of 100 ps or more. The fine time steps provide a detailed characterization of the cloud, allowing the independent estimation of processes contributing on differing time scales and providing sensitivity to the characteristic kinetic energies of the electrons making up the cloud. By varying the spacing and population of electron and positron beam bunches, we map the time development of the various cloud production and re-absorption processes. The excellent reproducibility of the measurements also permits the measurement of long-term conditioning of vacuum chamber surfaces.
Final version. 5 pages, 9 figures, 13 citations
References in corpus (1)
Cited by in corpus (5)
- In-Situ Measurements of the Secondary Electron Yield in an Accelerator Environment: Instrumentation and Methods
- Comparison of Electron Cloud Mitigating Coatings Using Retarding Field Analyzers
- Measurements of Electron Cloud Growth and Mitigation in Dipole, Quadrupole, and Wiggler Magnets
- Measurement of Electron Trapping in the CESR Storage Ring
- Measurement and Modeling of Electron Cloud in a Field Free Environment Using Retarding Field Analyzers