Feasibility guidelines for kaonic-atom experiments with ultra-high-resolution X-ray spectrometry
arXiv:1306.4147 · doi:10.1016/j.nuclphysa.2013.07.005
Abstract
Recent studies of strong interaction effects in kaonic atoms suggest that analysing so-called `lower' and `upper' levels in the same atom could separate one-nucleon absorption from multinucleon processes. The present work examines the feasibility of direct measurements of upper level widths in addition to lower level widths in future experiments, using superconducting microcalorimeter detectors. About ten elements are identified as possible candidates for such experiments, all of medium-weight and heavy nuclei. New experiments focused on achieving good accuracy for widths of such pairs of levels could contribute significantly to our knowledge of the -nucleon interaction in the nuclear medium.
arXiv comment13 pages, 5 figures, v2 -- table 1 added to introduction, To appear in Nucl. Phys. A
References in corpus (11)
- A New Measurement of Kaonic Hydrogen X rays
- In-medium nuclear interactions of low-energy hadrons
- Chiral SU(3) theory of antikaon-nucleon interactions with improved threshold constraints
- Improved constraints on chiral SU(3) dynamics from kaonic hydrogen
- Kaonic hydrogen X-ray measurement in SIDDHARTA
- - nucleus relativistic mean field potentials consistent with kaonic atoms
- Chirally motivated K^- nuclear potentials
- K^- nuclear potentials from in-medium chirally motivated models
- Experiments with atoms
- Kaonic atoms and in-medium K-N amplitudes II: interplay between theory and phenomenology
- Kaonic atoms and in-medium amplitudes