Night sky photometry and spectroscopy performed at the Vienna University Observatory
arXiv:1304.7716 · doi:10.1016/j.jqsrt.2013.08.019
Abstract
We present night sky brightness measurements performed at the Vienna University Observatory and at the Leopold-Figl-Observatorium fuer Astrophysik, which is located about 35km to the southwest of Vienna. The measurements have been performed with Sky Quality Meters made by Unihedron. They cover a time span of roughly one year and have been carried out every night, yielding a night sky brightness value every 7 seconds and thus delivering a large amount of data. In this paper, the level of light pollution at the Vienna University Observatory, which ranges from 15 to 19.25 magnitudes per square arcsecond, is presented for the very first time in a systematic way. We discuss the influence of different environmental conditions on the night sky brightness and implications for human vision. We show that the circalunar rhythm of night sky brightness is extinguished at our observatory due to light pollution. Additionally, we present spectra of the night sky in Vienna, taken with a 0.8m telescope. The goal of these spectroscopic measurements was to identify the main types of light sources and the spectral lines which cause the light pollution in Vienna. It turned out that fluorescent lamps are responsible for the strongest lines of the night sky above Vienna (e.g. lines at 546 nm and at 611 nm).
24 pages, 13 figures
References in corpus (2)
Cited by in corpus (21)
- Measuring night sky brightness: methods and challenges
- Sky Quality Meter measurements in a colour changing world
- Contributions of artificial lighting sources on light pollution in Hong Kong measured through a night sky brightness monitoring network
- The nature of the diffuse light near cities detected in nighttime satellite imagery
- Systematic measurements of the night sky brightness at 26 locations in Eastern Austria
- The night sky brightness at Potsdam-Babelsberg
- Human Contrast Threshold and Astronomical Visibility
- Evaluating the summer night sky brightness at a research field site on Lake Stechlin in northeastern Germany
- Sky Quality Meter and satellite correlation for the night cloud cover analysis at astronomical sites
- Testing sky brightness models against radial dependency: a dense two dimensional survey around the city of Madrid, Spain
- Monitoring transition: expected night sky brightness trends in different photometric bands
- Restoring the night sky darkness at Observatorio del Teide: First application of the model Illumina version 2
- Long-term trends of light pollution assessed from SQM measurements and an empirical atmospheric model
- Correcting Sky Quality Meter measurements for aging effects using twilight as calibrator
- Circalunar variations of the night sky brightness -- an FFT perspective on the impact of light pollution
- PSFs for mapping artificial night sky luminance over large territories
- Characterizing the zenithal night sky brightness in large territories: How many samples per square kilometer are needed?
- Variations on a classical theme: On the formal relationship between magnitudes per square arcsecond and luminance
- Spectroscopic study of the light-polluted night sky in Hong Kong
- Light pollution in shallow coastal waters: aquaculture farming in the Galician Atlantic shoreline
- A photometric mapping of the night sky brightness of the Maltese islands