paper

Developing AMS measurement of Ni at CIAE

arXiv:1304.3188

Abstract

Accelerator mass spectrometry (AMS) measurement of Ni has been established at CIAE with the HI-13 tandem accelerator and the recently developed -Q3D detection system. Ni standard and commercial NiO samples were measured to check the performance of the -Q3D detection system on Ni isobar separation and suppression. An overall suppression factor of about 10 for the interfering isobar Co resulting in detection sensitivity as low as 3.8 atomic ratio (Ni/Ni) has been obtained. Based on these techniques, the AMS measurement method of Ni with high sensitivity is developed.