Abstract
In a recent Letter [Phys. Rev. Lett. 109, 110502 (2012), arXiv:1204.6528], Bandyopadhyay, Paterek and Kaszlikowski report their analysis of spin coherence time in the radical pair involved in avian magnetoreception, concluding that is of the order of a microsecond. However, a combination of an erroneous numerical calculation together with an incorrect parameter drawn from an experimental source have resulted in the authors underestimating by two orders of magnitude. Consequently, one must reverse the authors' conclusion that the timescale is consistent with experiments on cryptochrome.
References in corpus (5)
Cited by in corpus (9)
- Vibrations, Quanta and Biology
- Chemical compass model for avian magnetoreception as a quantum coherent device
- Quantum Coherence and Entanglement in the Avian Compass
- The radical-pair mechanism as a paradigm for the emerging science of quantum biology
- Quantum dynamics of the avian compass
- Environment-induced anisotropy and the sensitivity of the radical pair mechanism in the avian compass
- Estimating the HF coupling parameters of the avian compass by comprehensively considering the available experimental results
- Retrodictive derivation of the radical-ion-pair master equation and Monte-Carlo simulation with single-molecule quantum trajectories
- Multiple re-encounter approach to radical pair reactions and the role of nonlinear master equations