Abstract
High precision measurements were made of reduced mobility, lateral and longitudinal diffusion of CS2- negative ions in 40 Torr CS2 and a 30 - 10 Torr CS2 - CF4 gas mixture. The reduced mobility was found to be 353.0 +/- 0.5 cm^2 Torr / s V in CS2 and 397.4 +/- 0.7 cm^2 Torr / s V in the CS2 - CF4 gas mixture at STP. The lateral diffusion temperatures for these two gases (295 +/- 15 K and 297 +/- 6 K) were found to be in good agreement with room temperature. By contrast longitudinal diffusion temperature was found to be slightly elevated (319 +/- 10 (stat) +/- 8 (sys) K and 310 +/- 20 (stat) +/- 6 (sys) K) though given the errors, room temperature diffusion can not be ruled out. For lateral diffusion significant capture distances (0.21 +/- 0.07 mm and 0.15 +/- 0.03 mm) were measured while for longitudinal diffusion the results were not conclusive.
Published by Review of Scientific Instruments but with some errors. These have been fixed. This version is more accurate than the published version
References in corpus (3)
Cited by in corpus (16)
- A review of the discovery reach of directional Dark Matter detection
- Readout technologies for directional WIMP Dark Matter detection
- Low Threshold Results and Limits from the DRIFT Directional Dark Matter Detector
- Gaseous and dual-phase time projection chambers for imaging rare processes
- The novel properties of SF for directional dark matter experiments
- Radon in the DRIFT-II directional dark matter TPC: emanation, detection and mitigation
- GEM-based TPC with CCD Imaging for Directional Dark Matter Detection
- First measurement of nuclear recoil head-tail sense in a fiducialised WIMP dark matter detector
- Reducing DRIFT Backgrounds with a Submicron Aluminized-Mylar Cathode
- Probing light vector mediators with coherent scattering at future facilities
- Coherent elastic neutrino-nucleus scattering with the BDX-DRIFT directional detector at next generation neutrino facilities
- Long-term study of backgrounds in the DRIFT-II directional dark matter experiment
- New Concept for Electron Beam-Dump Experiment Utilizing Directional WIMP Detector
- Background Assay and Rejection in DRIFT
- Measurement of directional range components of nuclear recoil tracks in a fiducialised dark matter detector
- CYGS: Detecting solar neutrinos with directional gas time projection chambers