Suitability of high-pressure xenon as scintillator for gamma ray spectroscopy
arXiv:1212.4050 · doi:10.1016/j.nima.2013.03.008
Abstract
In this paper we report the experimental study of high-pressure xenon used as a scintillator, in the context of developing a gamma ray detector. We measure a light yield near 2 photoelectrons per keV for xenon at 40 bar. Together with the light yield, we also measured an energy resolution of ~9% (FWHM) at 662 keV, dominated by the statistical fluctuations in the number of photoelectrons.
arXiv comment15 pages, 11 figures
References in corpus (8)
- Dark Matter Results from 100 Live Days of XENON100 Data
- Search for Neutrinoless Double-Beta Decay in Xe with EXO-200
- Liquid Xenon Detectors for Particle Physics and Astrophysics
- Technical Results from the Surface Run of the LUX Dark Matter Experiment
- Compton Imaging of MeV Gamma-Rays with the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)
- Primary and secondary scintillation measurements in a xenon Gas Proportional Scintillation Counter
- Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon
- A Study of the LXeGRIT Detection Efficiency for MeV Gamma-Rays during the 2000 Balloon Flight Campaign