Initial results of NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment
arXiv:1211.4838 · doi:10.1088/1748-0221/8/04/P04002
Abstract
NEXT-DEMO is a large-scale prototype of the NEXT-100 detector, an electroluminescent time projection chamber that will search for the neutrinoless double beta decay of Xe-136 using 100 to 150 kg of enriched xenon gas. NEXT-DEMO was built to prove the expected performance of NEXT-100, namely, energy resolution better than 1% FWHM at 2.5 MeV and event topological reconstruction. In this paper we describe the prototype and its initial results. A resolution of 1.75% FWHM at 511 keV (which extrapolates to 0.8% FWHM at 2.5 MeV) was obtained at 10 bar pressure using a gamma-ray calibration source. Also, a basic study of the event topology along the longitudinal coordinate is presented, proving that it is possible to identify the distinct dE/dx of electron tracks in high-pressure xenon using an electroluminescence TPC.
23 pages, 22 figures. Version accepted for publication by the Journal of Instrumentation (JINST)
References in corpus (1)
Cited by in corpus (15)
- Background rejection in NEXT using deep neural networks
- Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment
- Characterisation of NEXT-DEMO using xenon K X-rays
- Radiopurity assessment of the energy readout for the NEXT double beta decay experiment
- High Voltage in Noble Liquids for High Energy Physics
- Cosmogenic activation in double beta decay experiments
- Double Beta Decay APPEC Committee Report
- Status and prospects of the NEXT experiment for neutrinoless double beta decay searches
- The NEXT-100 Detector
- Double Beta Decay Experiments at Canfranc Underground Laboratory
- Bayesian network 3D event reconstruction in the Cygno optical TPC for dark matter direct detection
- First results of the NEXT-100 detector using Kr decays
- High Voltage Delivery and Distribution for the NEXT-100 Time Projection Chamber
- A journey to ITACA: Ion Tracking with Ammonium Cations Apparatus
- High Pressure Gas Xenon TPCs for Double Beta Decay Searches