Subtraction of test mass angular noise in the LISA Technology Package interferometer
arXiv:1203.4476 · doi:10.1007/s00340-007-2923-0
Abstract
We present recent sensitivity measurements of the LISA Technology Package interferometer with articulated mirrors as test masses, actuated by piezo-electric transducers. The required longitudinal displacement resolution of 9 pm/sqrt[Hz] above 3 mHz has been demonstrated with an angular noise that corresponds to the expected in on-orbit operation. The excess noise contribution of this test mass jitter onto the sensitive displacement readout was completely subtracted by fitting the angular interferometric data streams to the longitudinal displacement measurement. Thus, this cross-coupling constitutes no limitation to the required performance of the LISA Technology Package interferometry.
Applied Physics B - Lasers and Optics (2008)
Cited by in corpus (7)
- Deep phase modulation interferometry
- A compact high-precision periodic-error-free heterodyne interferometer
- Investigation and mitigation of noise contributions in a compact heterodyne interferometer
- Sub-pm/ non-reciprocal noise in the LISA backlink fiber
- Suspension platform interferometer for the AEI 10\,m prototype: concept, design and optical layout
- The end-to-end testbed of the Optical Metrology System on-board LISA Pathfinder
- Calibration of the in-orbit center-of-mass of TaiJi-1