Characterization of Alkali Metal Dispensers and Non-Evaporable Getter Pumps in Ultra-High Vacuum Systems for Cold Atomic Sensors
arXiv:1203.1202 · doi:10.1116/1.4757950
Abstract
A glass ultrahigh vacuum chamber with rubidium alkali metal dispensers and non-evaporable getter pumps has been developed and used to create a cold atomic sample in a chamber that operates with only passive vacuum pumps. The ion-mass spectrum of evaporated gases from the alkali metal dispenser has been recorded as a function of dispenser current. The efficacy of the non-evaporable getter pumps in promoting and maintaining vacuum has been characterized by observation of the Rb vapor optical absorption on the D2 transition at 780 nm and vacuum chamber pressure rate of rise tests. We have demonstrated a sample of laser-cooled Rb atoms in this chamber when isolated and operating without active vacuum pumps.
Cited by in corpus (9)
- ElecSus: A program to calculate the electric susceptibility of an atomic ensemble
- The Feasibility of a Fully Miniaturized Magneto-Optical Trap for Portable Ultracold Quantum Technology
- Compact chip-scale guided cold atom gyrometers for inertial navigation: Enabling technologies and design study
- Miniaturized optical frequency standard for next-generation portable optical clocks
- Invited Review: Micro-fabricated components for cold atom sensors
- Stand-alone vacuum cell for compact ultracold quantum technologies
- Reduction of helium permeation in microfabricated cells using aluminosilicate glass substrates and AlO coatings
- Alkali vapor pressure modulation on the 100ms scale in a single-cell vacuum system for cold atom experiments
- Pumping Dynamics of Cold-Atom Experiments in a Single Vacuum Chamber