Photomultiplier Tubes in the MiniBooNE Experiment
arXiv:1005.3525 · doi:10.1016/j.nima.2006.02.180
Abstract
The detector for the MiniBooNE experiment at the Fermi National Accelerator Laboratory employs 1520 8 inch Hamamatsu models R1408 and R5912 photomultiplier tubes with custom-designed bases. Tests were performed to determine the dark rate, charge and timing resolutions, double-pulsing rate, and desired operating voltage for each tube, so that the tubes could be sorted for optimal placement in the detector. Seven phototubes were tested to find the angular dependence of their response. After the Super-K phototube implosion accident, an analysis was performed to determine the risk of a similar accident with MiniBooNE.
arXiv comment25 pages, 19 figures
References in corpus (1)
Cited by in corpus (7)
- The MiniBooNE Detector
- Measurement of the Neutrino Neutral-Current Elastic Differential Cross Section
- The extended-track reconstruction for MiniBooNE
- Measurement of the Antineutrino Neutral-Current Elastic Differential Cross Section
- Cathode Position Response of Large-Area Photomultipliers Under a Magnetic Field
- Acquire information about neutrino parameters by detecting supernova neutrinos
- Simulation of large photomultipliers for experiments in astroparticle physics