Coronagraphic Low Order Wavefront Sensor: Principle and Application to a Phase-Induced Amplitude Coronagraph
arXiv:0911.1301 · doi:10.1088/0004-637X/693/1/75
Abstract
High contrast coronagraphic imaging of the immediate surrounding of stars requires exquisite control of low-order wavefront aberrations, such as tip-tilt (pointing) and focus. We propose an accurate, efficient and easy to implement technique to measure such aberrations in coronagraphs which use a focal plane mask to block starlight. The Coronagraphic Low Order Wavefront Sensor (CLOWFS) produces a defocused image of a reflective focal plane ring to measure low order aberrations. Even for small levels of wavefront aberration, the proposed scheme produces large intensity signals which can be easily measured, and therefore does not require highly accurate calibration of either the detector or optical elements. The CLOWFS achieves nearly optimal sensitivity and is immune from non-common path errors. This technique is especially well suited for high performance low inner working angle (IWA) coronagraphs. On phase-induced amplitude apodization (PIAA) type coronagraphs, it can unambiguously recover aberrations which originate from either side of the beam shaping introduced by the PIAA optics. We show that the proposed CLOWFS can measure sub-milliarcsecond telescope pointing errors several orders of magnitude faster than would be possible in the coronagraphic science focal plane alone, and can also accurately calibrate residual coronagraphic leaks due to residual low order aberrations. We have demonstrated 1e-3 lambda/D pointing stability in a laboratory demonstration of the CLOWFS on a PIAA type coronagraph.
References in corpus (6)
- Theoretical Limits on Extrasolar Terrestrial Planet Detection with Coronagraphs
- Exoplanets imaging with a Phase-Induced Amplitude Apodization Coronagraph - I. Principle
- Eighth-Order Image Masks for Terrestrial Planet Finding
- Tip-tilt Error in Lyot Coronagraphs
- Low Order Aberrations in Band-Limited Lyot Coronagraphs
- Diffraction-Based Sensitivity Analysis of Apodized Pupil Mapping Systems
Cited by in corpus (21)
- Fundamental limitations of high contrast imaging set by small sample statistics
- Calibration of quasi-static aberrations in exoplanet direct-imaging instruments with a Zernike phase-mask sensor
- On-sky speckle nulling demonstration at small angular separation with SCExAO
- High Contrast Imaging with an Arbitrary Aperture: Active Correction of Aperture Discontinuities
- Apodized pupil Lyot coronagraphs for arbitrary apertures. V. Hybrid Shaped Pupil designs for imaging Earth-like planets with future space observatories
- Lyot-based Low Order Wavefront Sensor for Phase-mask Coronagraphs: Principle, Simulations and Laboratory Experiments
- Estimation and correction of wavefront aberrations using the self-coherent camera: laboratory results
- On-sky performance of the QACITS pointing control technique with the Keck/NIRC2 vortex coronagraph
- Coronagraphic phase diversity: performance study and laboratory demonstration
- On-sky demonstration of low-order wavefront sensing and control with focal plane phase mask coronagraphs
- Astrophotonics: astronomy and modern optics
- Spectroscopic Coronagraphy for Planetary Radial Velocimetry of Exoplanets
- Coronagraphic Low Order Wave Front Sensor : post-processing sensitivity enhancer for high performance coronagraphs
- High-Contrast Coronagraphy
- EXCEDE Technology Development III: First Vacuum Tests
- Demonstration of broadband contrast at 1.2 /D and greater for the EXCEDE Starlight Suppression System
- High-contrast imager for Complex Aperture Telescopes (HiCAT): 2. Design overview and first light results
- Lyot-based Low Order Wavefront Sensor: Implementation on the Subaru Coronagraphic Extreme Adaptive Optics System and its Laboratory Performance
- Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC) on-sky demonstration with MagAO-X
- Focal plane wavefront control with model-based reinforcement learning
- Extinction controlled adaptive phase-mask coronagraph