Precise calibration of LIGO test mass actuators using photon radiation pressure
arXiv:0910.5591 · doi:10.1088/0264-9381/26/24/245011
Abstract
Precise calibration of kilometer-scale interferometric gravitational wave detectors is crucial for source localization and waveform reconstruction. A technique that uses the radiation pressure of a power-modulated auxiliary laser to induce calibrated displacements of one of the ~10 kg arm cavity mirrors, a so-called photon calibrator, has been demonstrated previously and has recently been implemented on the LIGO detectors. In this article, we discuss the inherent precision and accuracy of the LIGO photon calibrators and several improvements that have been developed to reduce the estimated voice coil actuator calibration uncertainties to less than 2 percent (1-sigma). These improvements include accounting for rotation-induced apparent length variations caused by interferometer and photon calibrator beam centering offsets, absolute laser power measurement using temperature-controlled InGaAs photodetectors mounted on integrating spheres and calibrated by NIST, minimizing errors induced by localized elastic deformation of the mirror surface by using a two-beam configuration with the photon calibrator beams symmetrically displaced about the center of the optic, and simultaneously actuating the test mass with voice coil actuators and the photon calibrator to minimize fluctuations caused by the changing interferometer response. The photon calibrator is able to operate in the most sensitive interferometer configuration, and is expected to become a primary calibration method for future gravitational wave searches.
arXiv comment13 pages, 6 figures, accepted by Classical and Quantum Gravity
References in corpus (3)
Cited by in corpus (21)
- Advanced LIGO
- GW150914: The Advanced LIGO Detectors in the Era of First Discoveries
- Open data from the first and second observing runs of Advanced LIGO and Advanced Virgo
- The Sensitivity of the Advanced LIGO Detectors at the Beginning of Gravitational Wave Astronomy
- Calibration of the LIGO Gravitational Wave Detectors in the Fifth Science Run
- Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
- Gravitational Waves: Sources, Detectors and Searches
- Multi-band gravitational-wave astronomy: parameter estimation and tests of general relativity with space and ground-based detectors
- The Advanced LIGO Photon Calibrators
- Effect of calibration errors on Bayesian parameter estimation for gravitational wave signals from inspiral binary systems in the advanced detectors era
- Validating gravitational-wave detections: The Advanced LIGO hardware injection system
- First all-sky search for continuous gravitational waves from unknown sources in binary systems
- Possible Causes of False General Relativity Violations in Gravitational Wave Observations
- Fiducial displacements with improved accuracy for the global network of gravitational wave detectors
- Improving the absolute accuracy of the gravitational wave detectors by combining the photon pressure and gravity field calibrators
- Accurate calibration of test mass displacement in the LIGO interferometers
- Reconstruction of the gravitational wave signal during the Virgo science runs and independent validation with a photon calibrator
- Calibration of the LIGO displacement actuators via laser frequency modulation
- Effects of calibration uncertainties on the detection and parameter estimation of isotropic gravitational-wave backgrounds
- Development of advanced photon calibrator for Kamioka gravitational wave detector (KAGRA)
- Photon Calibration Performance of KAGRA during the 4th Joint Observing Run (O4)