Temperature Dependence and Screening Models in Quantum Cascade Structure
arXiv:0908.4159 · doi:10.1063/1.3226072
Abstract
Different screening models in quantum cascade lasers are compared by calculating the contribution of intra-subband impurity scattering to the optical linewidth as a function of temperature. We find a strong impact of impurity scattering which is increasing substantially with temperature. A simple isotropic bulk screening model works well if the screening length is of the order or longer than the period length of the cascade structure.
7 pages, 9 figures
References in corpus (2)
Cited by in corpus (6)
- Modeling techniques for quantum cascade lasers
- Electron transport in quantum wire superlattices
- Contrasting influence of charged impurities on transport and gain in terahertz quantum cascade lasers
- Optoelectronic device simulations based on macroscopic Maxwell-Bloch equations
- Density matrix Monte Carlo modeling of quantum cascade lasers
- Density Matrix Modeling of Quantum Cascade Lasers without an Artificially Localized Basis: A Generalized Scattering Approach