Detrended Fluctuation Analysis of Systolic Blood Pressure Control Loop
arXiv:0908.3614 · doi:10.1088/1367-2630/11/10/103005
Abstract
We use detrended fluctuation analysis (DFA) to study the dynamics of blood pressure oscillations and its feedback control in rats by analyzing systolic pressure time series before and after a surgical procedure that interrupts its control loop. We found, for each situation, a crossover between two scaling regions characterized by exponents that reflect the nature of the feedback control and its range of operation. In addition, we found evidences of adaptation in the dynamics of blood pressure regulation a few days after surgical disruption of its main feedback circuit. Based on the paradigm of antagonistic, bipartite (vagal and sympathetic) action of the central nerve system, we propose a simple model for pressure homeostasis as the balance between two nonlinear opposing forces, successfully reproducing the crossover observed in the DFA of actual pressure signals.
References in corpus (8)
- Detecting Long-range Correlations with Detrended Fluctuation Analysis
- Effect of Trends on Detrended Fluctuation Analysis
- Effect of nonstationarities on detrended fluctuation analysis
- Comparison of detrending methods for fluctuation analysis
- Correlation Differences in Heartbeat Fluctuations During Rest and Exercise
- Fractal scale-invariant and nonlinear properties of cardiac dynamics remain stable with advanced age: A new mechanistic picture of cardiac control in healthy elderly
- 1/f Scaling in Heart Rate Requires Antagonistic Autonomic Control
- Fractal Rigidity in Migraine