MIMAC : a micro-TPC detector for non-baryonic dark matter search
arXiv:0905.4697 · doi:10.1051/eas/0936037
Abstract
The MIMAC project is multi-chamber detector for Dark Matter search, aiming at measuring both track and ionization with a matrix of micromegas micro-TPC filled with He3 and CF4. Recent experimental results on the first measurements of the Helium quenching factor at low energy (1 keV recoil) are presented.
arXiv comment7 pages, Proc of Dark Energy and Dark Matter conference, Lyon : France (2008)
References in corpus (12)
- A direct empirical proof of the existence of dark matter
- The 3D power spectrum of galaxies from the SDSS
- Micromegas in a Bulk
- Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment
- Optimizing WIMP directional detectors
- SICANE: a Detector Array for the Measurement of Nuclear Recoil Quenching Factors using Monoenergetic Neutron Beam
- The CMB temperature power spectrum from an improved analysis of the Archeops data
- Supersymmetric dark matter search via spin-dependent interaction with He3
- Low-background applications of MICROMEGAS detector technology
- Search for Supersymmetric Dark Matter with Superfluid He3 (MACHe3)
- An analysis method for time ordered data processing of Dark Matter experiments
- MIMAC : Detection of low energy recoils for Dark Matter search