Highly Sensitive Gamma-Spectrometers of GERDA for Material Screening: Part 2
arXiv:0812.0768
Abstract
The previous article about material screening for GERDA points out the importance of strict material screening and selection for radioimpurities as a key to meet the aspired background levels of the GERDA experiment. This is directly done using low-level gamma-spectroscopy. In order to provide sufficient selective power in the mBq/kg range and below, the employed gamma-spectrometers themselves have to meet strict material requirements, and make use of an elaborate shielding system. This article gives an account of the setup of two such spectrometers. Corrado is located in a depth of 15 m w.e. at the MPI-K in Heidelberg (Germany), GeMPI III is situated at the Gran-Sasso underground laboratory at 3500 m w.e. (Italy). The latter one aims at detecting sample activities of the order ~0.01 mBq/kg, which is the current state-of-the-art level. The applied techniques to meet the respective needs are discussed and demonstrated by experimental results.
Featured in: Proceedings of the XIV International Baksan School "Particles and Cosmology" Baksan Valley, Kabardino-Balkaria, Russia, April 16-21,2007. INR RAS, Moscow 2008. ISBN 978-5-94274-055-9, pp. 233-238; (6 pages, 4 figures)
Cited by in corpus (6)
- Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
- Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements
- Status of the GERDA experiment aimed to search for neutrinoless double beta decay of 76Ge
- Assay methods for U-238, Th-232, and Pb-210 in lead and calibration of Bi-210 bremsstrahlung emission from lead
- Material Screening with HPGe Counting Station for PandaX Experiment
- On the omnipresent background gamma radiation of the continuous spectrum