CCCP: A CCD Controller for Counting Photons
arXiv:0807.0363 · doi:10.1117/12.788929
Abstract
CCCP, a CCD Controller for Counting Photons, is presented. This new controller uses a totally new clocking architecture and allows to drive the CCD in a novel way. Its design is optimized for the driving of EMCCDs at up to 20MHz of pixel rate and fast vertical transfer. Using this controller, the dominant source of noise of EMCCDs at low flux level and high frame rate, the Clock Induced Charges, were reduced to 0.001 - 0.0018 electron/pixel/frame (depending of the electron multiplying gain), making efficient photon counting possible. CCCP will be deployed in 2009 on the ESO NTT through the 3D-NTT1 project and on the SOAR through the BTFI project.
10 pages, 10 figures, to appear in "Ground-based and Airborne Instrumentation for Astronomy II" SPIE conference, Marseille, 23-28 June 2008
References in corpus (1)
Cited by in corpus (5)
- FIREBall-2: The Faint Intergalactic Medium Redshifted Emission Balloon Telescope
- Single-grain dose-distribution measurements by optically stimulated luminescence using an integrated EMCCD-based system
- Simulating the WFIRST coronagraph Integral Field Spectrograph
- Statistics of electron-multiplying charge-coupled devices
- BTFI2: a simple, light and compact Fabry-Perot instrument for the SOAR telescope