Digital pulse-shape discrimination of fast neutrons and gamma rays
arXiv:0805.0692 · doi:10.1016/j.nima.2008.06.004
Abstract
Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator detector, and a BaF2 detector was used to collect waveforms with a 100 Ms/s, 14 bit sampling ADC. Three identical ADC's were combined to increase the sampling frequency to 300 Ms/s. Four different digital pulse-shape analysis algorithms were developed and compared to each other and to data obtained with an analogue neutron-gamma discrimination unit. Two of the digital algorithms were based on the charge comparison method, while the analogue unit and the other two digital algorithms were based on the zero-crossover method. Two different figure-of-merit parameters, which quantify the neutron-gamma discrimination properties, were evaluated for all four digital algorithms and for the analogue data set. All of the digital algorithms gave similar or better figure-of-merit values than what was obtained with the analogue setup. A detailed study of the discrimination properties as a function of sampling frequency and bit resolution of the ADC was performed. It was shown that a sampling ADC with a bit resolution of 12 bits and a sampling frequency of 100 Ms/s is adequate for achieving an optimal neutron-gamma discrimination for pulses having a dynamic range for deposited neutron energies of 0.3-12 MeV. An investigation of the influence of the sampling frequency on the time resolution was made. A FWHM of 1.7 ns was obtained at 100 Ms/s.
26 pages, 14 figures, submitted to Nuclear Instruments and Methods in Physics Research A
References in corpus (2)
Cited by in corpus (9)
- Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass
- Characterization of a Li-6 loaded liquid organic scintillator for fast neutron spectrometry and thermal neutron detection
- Discrete Fourier Transform Method for Discrimination of Digital Scintillation Pulses in Mixed Neutron-Gamma Fields
- Use of polyethylene naphthalate as a self-vetoing structural material
- Improved Pulse Shape Discrimination in EJ-301 liquid scintillators
- Performance of The Advanced GAmma Tracking Array at GANIL
- Measuring Fast Neutrons with Large Liquid Scintillation Detector for Ultra-low Background Experiments
- Separation of gamma-ray and neutron events with CsI(Tl) pulse shape analysis
- Development of Neutron Detectors for the Next Generation of Radioactive Ion-Beam Facilities