Noise invoked resonances near a homoclinic bifurcation in the glow discharge plasma
arXiv:0803.2140 · doi:10.1103/PhysRevE.78.026406
Abstract
Stochastic Resonance (SR) and Coherence Resonance (CR) have been studied experimentally in the discharge plasma close to a homoclinic bifurcation. For the SR phenomena, it is observed that a superimposed subthreshold periodic signal can be recovered via stochastic modulations of the discharge voltage. Furthermore, it is realized that even in the absence of a subthreshold deterministic signal, the system dynamics can be recovered and optimized using noise. This effect is defined as CR in the literature. In the present experiments, induction of SR and CR are quantified using the Absolute Mean Difference (AMD) and Normalized Variance (NV) techniques respectively. AMD is a new statistical tool to quantify regularity in the stochastic resonance and is independent of lag.
6 page
References in corpus (1)
Cited by in corpus (7)
- Continuous wavelet transform based time-scale and multi-fractal analysis of the nonlinear oscillations in a hollow cathode glow discharge plasma
- Intrinsic Noise Induced Coherence Resonance in a Glow discharge Plasma
- Coherence resonance in an unijunction transistor relaxation oscillator
- Doubly Forced Anharmonic Oscillator Model for Floating Potential Fluctuations in DC Glow Discharge Plasma
- Modeling noise induced resonance in an excitable system: An alternative approach
- Emergence of the stochastic resonance in glow discharge plasma
- Bifurcation analysis of a two-neuron central pattern generator model for both oscillatory and convergent neuronal activities