Temperature and Humidity Dependence of Air Fluorescence Yield measured by AIRFLY
arXiv:0711.4583 · doi:10.1016/j.nima.2008.08.050
Abstract
The fluorescence detection of ultra high energy cosmic rays requires a detailed knowledge of the fluorescence light emission from nitrogen molecules over a wide range of atmospheric parameters, corresponding to altitudes typical of the cosmic ray shower development in the atmosphere. We have studied the temperature and humidity dependence of the fluorescence light spectrum excited by MeV electrons in air. Results for the 313.6 nm, 337.1 nm, 353.7 nm and 391.4 nm bands are reported in this paper. We found that the temperature and humidity dependence of the quenching process changes the fluorescence yield by a sizeable amount (up to 20%) and its effect must be included for a precise estimation of the energy of ultra high energy cosmic rays.
arXiv commentpresented at the 5th Fluorescence Workshop, El Escorial - Madrid, Spain, 16 - 20 September 2007, to appear in Nuclear Instruments and Methods A
References in corpus (6)
- New measurement on photon yields from air and the application to the energy estimation of primary cosmic rays
- Measurement of the pressure dependence of air fluorescence emission induced by electrons
- Photon yields from nitrogen gas and dry air excited by electrons
- Measurement of air and nitrogen fluorescence light yields induced by electron beam for UHECR experiments
- Measurement of Pressure Dependent Fluorescence Yield of Air: Calibration Factor for UHECR Detectors
- A novel method for the absolute fluorescence yield measurement by AIRFLY
Cited by in corpus (17)
- The Fluorescence Detector of the Pierre Auger Observatory
- Measurement of the cosmic-ray energy spectrum above eV using the Pierre Auger Observatory
- Features of the energy spectrum of cosmic rays above eV using the Pierre Auger Observatory
- Description of Atmospheric Conditions at the Pierre Auger Observatory using the Global Data Assimilation System (GDAS)
- Air Fluorescence Relevant for Cosmic-Ray Detection - Summary of the 5th Fluorescence Workshop, El Escorial 2007
- Precise measurement of the absolute fluorescence yield of the 337 nm band in atmospheric gases
- The Rapid Atmospheric Monitoring System of the Pierre Auger Observatory
- A novel method for the absolute fluorescence yield measurement by AIRFLY
- On the absolute value of the air-fluorescence yield
- Nitrogen fluorescence in air for observing extensive air showers
- Description of Atmospheric Conditions at the Pierre Auger Observatory Using Meteorological Measurements and Models
- The impact of the air-fluorescence yield on the reconstructed shower parameters of ultra-high energy cosmic rays
- Precise Measurement of the Absolute Yield of Fluorescence Photons in Atmospheric Gases
- Relevance of the fluorescence radiation in VHE gamma-ray observations with the Cherenkov technique
- The Air-Fluorescence Yield
- The effect of the Fluorescence Yield selection on the energy scales of Auger, HiRes and TA
- Ground Truth calibration for the JEM-EUSO Mission