Unrecognized Backscattering in Low Energy Beta Spectroscopy
arXiv:0708.3150 · doi:10.1016/j.nima.2007.11.016
Abstract
We present studies on electron backscattering from the surface of plastic scintillator beta detectors. By using a setup of two detectors coaxial with a strong external magnetic field - one detector serving as primary detector, the other as veto-detector to detect backscattering - we investigate amount and spectrum of unrecognized backscattering, i.e. events where only one detector recorded a trigger signal. The implications are important for low energy particle physics experiments.
5 pages, 8 figures; v2: published NIM A version
References in corpus (6)
- Is the Unitarity of the quark-mixing-CKM-matrix violated in neutron -decay?
- Experiments in Fundamental Neutron Physics
- Measurement of the Neutrino Asymmetry Parameter B in Neutron Decay
- Measurement of Electron Backscattering in the Energy Range of Neutron -Decay
- New Measurements and Quantitative Analysis of Electron Backscattering in the Energy Range of Neutron Beta-Decay
- A Backscatter-Suppressed Beta Spectrometer for Neutron Decay Studies
Cited by in corpus (8)
- Determination of the Weak Axial Vector Coupling from a Measurement of the Beta-Asymmetry Parameter A in Neutron Beta Decay
- Precision Measurement of the Neutron Beta-Decay Asymmetry
- A clean, bright, and versatile source of neutron decay products
- Measurement of the Proton Asymmetry Parameter C in Neutron Beta Decay
- Constraints on the Dark Matter Interpretation of the Neutron Decay Anomaly with the PERKEO II experiment
- A solenoidal electron spectrometer for a precision measurement of the neutron -asymmetry with ultracold neutrons
- Undetected Electron Backscattering in PERKEO III
- Characterization of electron detectors by time-of-flight in neutron \b{eta} decay experiments