most citedMedical Deep Learning -- A systematic Meta-Review

259 citations

Showing physics.med-phShow all

7 papers · 1 filter

physics.med-ph2022

Characterization of pixelated silicon detectors for daily quality assurance measurements in proton therapy

Isabelle Schilling, Claus Maximillian Bäcker, Christian Bäumer +4

The advanced imaging and delivery techniques in proton therapy allow conformal high-dose irradiation of the target volume with high accuracy using pencil beam scanning or beam shap…

physics.med-ph2018★ 11 cited

A study of the irradiation technique used for the external beam radiotherapy of retinoblastoma

L. Brualla, P. A. Mayorga, A. Flühs +3

Purpose: Retinoblastoma (RB) is the most common eye tumor in childhood and can be treated external radiotherapy. The purpose of this work is to evaluate the adequacy of Monte Carlo…

physics.med-ph2018★ 6 cited

Monte Carlo study for designing a dedicated `D'-shaped collimator used in the external beam radiotherapy of retinoblastoma patients

P. A. Mayorga, L. Brualla, W. Sauerwein +1

Purpose: The purpose of the present article is to propose a modified version of the D-shaped collimator used at the Univ. Hosp. of Essen for retinoblastoma treatment that reduces e…

physics.med-ph2018★ 2 cited

Testing Monte Carlo absolute dosimetry formalisms for a small field `D'-shaped collimator used in retinoblastoma external beam radiotherapy

P. A. Mayorga, L. Brualla, A. Flühs +2

Purpose: To investigate the validity of two Monte Carlo simulation absolute dosimetry approaches in the case of a small field dedicated `D'-shaped collimator used for the retinobla…

physics.med-ph2018★ 10 cited

Computation of the electron beam quality factors for the NE2571, NE2571A and NE2581A thimble ionization chambers using PENELOPE

F. Erazo, L. Brualla, A. M. Lallena

The quality correction factor for electron beams was calculated for three thimble ionization chambers, namely, NE2571, NE2571A and NE2581A. The Monte Carlo code PENEL…

physics.med-ph2016★ 4 cited

Clinical Validation of two Surface Imaging Systems for Patient Positioning in Percutaneous Radiotherapy

Manfred Wiencierz, Kathrin Kruppa, Lutz Lüdemann

Precise patient positioning and thus precise positioning of the planning target volume (PTV) is a prerequisite for effective treatment in percutaneous radiation therapy. Convention…

physics.med-ph2015★ 40 cited

A geometrical model for the Monte Carlo simulation of the TrueBeam linac

Miguel Rodriguez, Josep Sempau, Antonella Fogliata +3

Monte Carlo (MC) simulation of linacs depends on the accurate geometrical description of the head. The geometry of the Varian TrueBeam (TB) linac is not available to researchers. I…