10.9k citations
Counting papers with at most 25 authors, so collaboration author lists do not stand in for the people here.
- Commissariat à l'Énergie Atomique et aux Énergies AlternativesFR7.4k papers
- Centre National de la Recherche ScientifiqueFR6k papers
- CEA Paris-SaclayFR5k papers
- Institut National de Physique Nucléaire et de Physique des ParticulesFR4.3k papers
- Université Paris-SaclayFR3.1k papers
- The Ohio State UniversityUS3k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma IIT3k papers
- European Organization for Nuclear ResearchCH3k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di BolognaIT2.9k papers
- Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di FrascatiIT2.9k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di GenovaIT2.7k papers
- Rutherford Appleton LaboratoryGB2.6k papers
13 papers · 2 filters
Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors
D. Abbaneo, M. Abbas, M. Abbrescia +153
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and…
Sealed operation, and circulation and purification of gas in the HARPO TPC
M. Frotin, P. Gros, D. Attié +9
HARPO is a time projection chamber (TPC) demonstrator of a gamma-ray telescope and polarimeter in the MeV-GeV range, for a future space mission. We present the evolution of the TPC…
Fast-neutron induced background in LaBr3:Ce detectors
J. Kiener, V. Tatischeff, I. Deloncle +17
The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce crystal to incident neutrons has been measured in the energy range En = 2-12 MeV. Neutrons were produc…
Background suppression in massive TeO bolometers with Neganov-Luke amplified light detectors
N. Casali, L. Dumoulin, A. Giuliani +13
Bolometric detectors are excellent devices for the investigation of neutrinoless double-beta decay (0). The observation of such decay would demonstrate the violation of lepton…
Development of Wireless Techniques in Data and Power Transmission - Application for Particle Physics Detectors
R. Brenner, S. Ceuterickx, C. Dehos +15
Wireless techniques have developed extremely fast over the last decade and using them for data and power transmission in particle physics detectors is not science- fiction any more…
A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research
F. Aznar, J. Castel, F. E. Christensen +18
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbu…
Online Monitoring of the Osiris Reactor with the Nucifer Neutrino Detector
G. Boireau, L. Bouvet, A. P. Collin +51
Originally designed as a new nuclear reactor monitoring device, the Nucifer detector has successfully detected its first neutrinos. We provide the second shortest baseline measurem…
Time calibration with atmospheric muon tracks in the ANTARES neutrino telescope
S. Adrián-Martínez, A. Albert, M. André +127
The ANTARES experiment consists of an array of photomultipliers distributed along 12 lines and located deep underwater in the Mediterranean Sea. It searches for astrophysical neutr…
Lessons from the operation of the "Penning-Fluorescent" TPC and prospects
Diego Gonzalez-Diaz, F. Aznar, J. Castel +15
We have recently reported the development of a new type of high-pressure Xenon time projection chamber operated with an ultra-low diffusion mixture and that simultaneously displays…
Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres
Diego Gonzalez-Diaz, V. Alvarez, F. I. G. Borges +80
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with t…
Low Background Micromegas in CAST
J. G. Garza, S. Aune, D. Calvet +22
Solar axions could be converted into x-rays inside the strong magnetic field of an axion helioscope, triggering the detection of this elusive particle. Low background x-ray detecto…
SAMPIC: a readout chip for fast timing detectors in particle physics and medical imaging
C. Royon
We describe the new fast timing readout chip SAMPIC developed in CEA Saclay and in LAL Orsay (France) as well as the results of differents tests performed using that chip.
ORIGAMIX, a CdTe-based spectro-imager development for nuclear applications
S. Dubos, H. Lemaire, S. Schanne +4
The Astrophysics Division of CEA Saclay has a long history in the development of CdTe based pixelated detection planes for X and gamma-ray astronomy, with time-resolved imaging and…