output
20042024
most citedRandom Forest-Based Prediction of Stroke Outcome

135 citations

Showing physics.med-phShow all

7 papers · 1 filter

physics.med-ph2024★ 2 cited

Evaluation of the two-voltage method for parallel-plate ionization chambers irradiated with pulsed beams

José Paz-Martín, Andreas Schüller, Alexandra Bourgouin +5

Air-vented ionization chambers exposed to clinical radiation beams may suffer from recombination during the drift of the charge carriers towards the electrodes. Thus, dosimetry pro…

physics.med-ph2023★ 4 cited

An in-silico study of conventional and FLASH radiotherapy iso-effectiveness: Radiolytic oxygen depletion and its potential impact on tumor control probability

Isabel González-Crespo, Faustino Gómez, Óscar López Pouso +1

FLASH radiotherapy (FLASH-RT) has shown the potential to spare normal tissue while seemingly maintaining the effectiveness of conventional radiotherapy (CONV-RT). It has been sugge…

physics.med-ph2023★ 2 cited

Variation of the relative biological effectiveness with fractionation in proton therapy: analysis of prostate cancer response

Juan Pardo-Montero, Miguel Pombar, Antonio Gómez-Caamaño +2

Purpose: To present a methodology to analyze the variation of RBE with fractionation from clinical data of tumor control probability (TCP) and to apply it to study the response of…

physics.med-ph2022★ 8 cited

Quantification of internal dosimetry in PET patients II: Individualized Monte Carlo-based dosimetry for [18F]Fluorocholine PET

Sara Neira, Jacobo Guiu-Souto, Paulino Pais +7

Purpose: To obtain individualized internal doses with a Monte Carlo method in patients undergoing diagnostic FCH-PET studies and to compare such doses with the MIRD method calculat…

physics.med-ph2021★ 1 cited

A Mathematical Model of Thyroid Disease Response to Radiotherapy

Araceli Gago-Arias, Sara Neira, Filippo Terragni +1

We present a mechanistic biomathematical model of molecular radiotherapy of thyroid disease. The general model consists of a set of differential equations describing the dynamics o…

physics.med-ph2021★ 10 cited

A kinetic model of continuous radiation damage to populations of cells: Comparison to the LQ model and application to molecular radiotherapy

Sara Neira, Araceli Gago-Arias, Jacobo Guiu-Souto +1

The linear-quadratic (LQ) model to describe the survival of irradiated cells may be the most frequently used biomathematical model in radiotherapy. There has been an intense debate…

physics.med-ph2004★ 28 cited

Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance

J. Pardo, L. Franco, F. Gomez +7

A liquid isooctane (CH) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, eac…