9.8k citations
Counting papers with at most 25 authors, so collaboration author lists do not stand in for the people here.
- Gran Sasso Science InstituteIT850 papers
- Istituto Nazionale di Fisica NucleareIT577 papers
- Centre National de la Recherche ScientifiqueFR505 papers
- University of L'AquilaIT502 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di NapoliIT424 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma IIT413 papers
- Sapienza University of RomeIT394 papers
- Institut National de Physique Nucléaire et de Physique des ParticulesFR379 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di GenovaIT330 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di MilanoIT316 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di Milano BicoccaIT303 papers
- Istituto Nazionale di Fisica Nucleare, Sezione di PadovaIT299 papers
17 papers · 2 filters
Li-containing scintillating bolometers for low background physics
L. Pattavina
We present the performances of Li-based compounds used as scintillating bolometer for rare decay studies such as double-beta decay and direct dark matter investigations. The compou…
Observation and applications of single-electron charge signals in the XENON100 experiment
E. Aprile, M. Alfonsi, K. Arisaka +77
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Intera…
Neutrino physics with multi-ton scale liquid xenon detectors
L. Baudis, A. Ferella, A. Kish +3
We study the sensitivity of large-scale xenon detectors to low-energy solar neutrinos, to coherent neutrino-nucleus scattering and to neutrinoless double beta decay. As a concrete…
Development of a Li2MoO4 scintillating bolometer for low background physics
L. Cardani, N. Casali, S. Nagorny +16
We present the performance of a 33 g Li2MoO4 crystal working as a scintillating bolometer. The crystal was tested for more than 400 h in a dilution refrigerator installed in the un…
Pulse shape discrimination for GERDA Phase I data
M. Agostini, M. Allardt, E. Andreotti +111
The GERDA experiment located at the LNGS searches for neutrinoless double beta (0νββ) decay of ^{76}Ge using germanium diodes as source and detector. In Phase I of the experiment e…
A study of electron recombination using highly ionizing particles in the ArgoNeuT Liquid Argon TPC
R. Acciarri, C. Adams, J. Asaadi +29
Electron recombination in highly ionizing stopping protons and deuterons is studied in the ArgoNeuT detector. The data are well modeled by either a Birks model or a modified form o…
Observation of the Dependence of Scintillation from Nuclear Recoils in Liquid Argon on Drift Field
T. Alexander, H. O. Back, H. Cao +27
We have exposed a dual-phase Liquid Argon Time Projection Chamber (LAr-TPC) to a low energy pulsed narrowband neutron beam, produced at the Notre Dame Institute for Structure and N…
The background in the neutrinoless double beta decay experiment GERDA
The GERDA collaboration, M. Agostini, M. Allardt +111
The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double beta decay of 76Ge. The signature of th…
Search for ν_τ interactions with the nuclear emulsion films of the OPERA experiment
Fabio Pupilli
The OPERA experiment aims at measuring the ν_μ -> ν_τ oscillation through the ν_τ appearance in an almost pure ν_μ beam (CNGS). For the direct identification of the short-lived τ l…
Light output response of the LVD liquid scintillator to neutron-induced nuclear recoils
G. Bruno
The organic liquid scintillator used in the LVD experiment (INFN Gran Sasso National Laboratory) has been exposed to an Am-Be neutron source to measure the light response function…
Cosmogenic Backgrounds in Borexino at 3800 m water-equivalent depth
G. Bellini, J. Benziger, D. Bick +86
The solar neutrino experiment Borexino, which is located in the Gran Sasso underground laboratories, is in a unique position to study muon-induced backgrounds in an organic liquid…
VUV-Vis optical characterization of Tetraphenyl-butadiene films on glass and specular reflector substrates from room to liquid Argon temperature
R. Francini, R. M. Montereali, E. Nichelatti +8
The use of efficient wavelength-shifters from the vacuum-ultraviolet to the photosensor's range of sensitivity is a key feature in detectors for Dark Matter search and neutrino phy…
Isotopically modified Ge detectors for {\sc Gerda}: from production to operation
D. Budjáš, M. Agostini, L. Baudis +21
The \textsc{Gerda} experiment searches for the neutrinoless double beta (beta^{76}^{76}$Ge…
Monte Carlo Studies and Optimization for the Calibration System of the GERDA Experiment
Laura Baudis, Alfredo D. Ferella, Francis Froborg +1
The GERmanium Detector Array, GERDA, searches for neutrinoless double beta decay in Ge-76 using bare high-purity germanium detectors submerged in liquid argon. For the calibration…
Performances of a large mass ZnSe bolometer to search for rare events
J. W. Beeman, F. Bellini, L. Cardani +16
Scintillating bolometers of ZnSe are the baseline choice of the LUCIFER experiment, whose aim is to observe the neutrinoless double beta decay of 82Se. The independent read-out of…
CdWO4 crystal scintillators from enriched isotopes for double beta decay experiments
D. V. Poda, A. S. Barabash, P. Belli +32
Cadmium tungstate crystal scintillators enriched in 106Cd and 116Cd were developed. The produced scintillators exhibit good optical and scintillation properties, and a low level of…
HEROICA: an Underground Facility for the Fast Screening of Germanium Detectors
E. Andreotti, A. Garfagnini, W. Maneschg +29
An infrastructure to characterize germanium detectors has been designed and constructed at the HADES Underground Research Laboratory, located in Mol (Belgium). Thanks to the 223m o…