Counting papers with at most 25 authors, so collaboration author lists do not stand in for the people here.
- Sapienza University of RomeIT5.6k papers
- Centre National de la Recherche ScientifiqueFR4.7k papers
- Institut National de Physique Nucléaire et de Physique des ParticulesFR4.3k papers
- Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di FrascatiIT4.2k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di BolognaIT4k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di PisaIT4k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di GenovaIT3.8k papers
- European Organization for Nuclear ResearchCH3.6k papers
- Commissariat à l'Énergie Atomique et aux Énergies AlternativesFR3.5k papers
- Rutherford Appleton LaboratoryGB3.5k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di NapoliIT3.4k papers
- The Ohio State UniversityUS3.2k papers
16 papers · 2 filters
CALDER: cryogenic light detector for rare events search
L. Pagnanini, E. S. Battistelli, F. Bellini +15
The CALDER project aims at developing cryogenic light detectors with high sensitivity to UV and visible light, to be used for particle tagging in massive bolometers. Indeed the sen…
Background suppression in massive TeO bolometers with Neganov-Luke amplified light detectors
N. Casali, L. Dumoulin, A. Giuliani +13
Bolometric detectors are excellent devices for the investigation of neutrinoless double-beta decay (0). The observation of such decay would demonstrate the violation of lepton…
Characterization of the KID-Based Light Detectors of CALDER
N. Casali, F. Bellini, L. Cardani +10
The aim of the Cryogenic wide-Area Light Detectors with Excellent Resolution (CALDER) project is the development of light detectors with active area of cm and noise…
Polycrystalline para-terphenyl scintillator adopted in a detecting probe for radio-guided surgery
Elena Solfaroli Camillocci, Fabio Bellini, Valerio Bocci +15
A radio-guided surgery technique exploiting emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical…
High granularity tracker based on a Triple-GEM optically read by a CMOS-based camera
Michela Marafini, Vincenzo Patera, Davide Pinci +3
The detection of photons produced during the avalanche development in gas chambers has been the subject of detailed studies in the past. The great progresses achieved in last years…
Double-beta decay investigation with highly pure enriched Se for the LUCIFER experiment
J. W. Beeman, F. Bellini, P. Benetti +26
The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of Se. The matrix which em…
Time calibration with atmospheric muon tracks in the ANTARES neutrino telescope
S. Adrián-Martínez, A. Albert, M. André +127
The ANTARES experiment consists of an array of photomultipliers distributed along 12 lines and located deep underwater in the Mediterranean Sea. It searches for astrophysical neutr…
Long term monitoring of the optical background in the Capo Passero deep-sea site with the NEMO tower prototype
S. Adrián-Martínez, S. Aiello, F. Ameli +101
The NEMO Phase-2 tower is the first detector which was operated underwater for more than one year at the "record" depth of 3500 m. It was designed and built within the framework of…
Performance of a Tungsten-Cerium Fluoride Sampling Calorimeter in High-Energy Electron Beam Tests
R. Becker, L. Bianchini, G. Dissertori +29
A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams…
CALDER - Neutrinoless double-beta decay identification in TeO bolometers with kinetic inductance detectors
E. S. Battistelli, F. Bellini, C. Bucci +16
Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10 meV. CUORE, an array of 988 TeO bolometers b…
Response of microchannel plates to single particles and to electromagnetic showers
L. Brianza, F. Cavallari, D. Del Re +22
We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electr…
Design and realization of a facility for the characterization of Silicon Avalanche PhotoDiodes
Andrea Celentano, Luca Colaneri, Raffaella De Vita +7
We present the design, construction, and performance of a facility for the characterization of Silicon Avalanche Photodiodes in the operating temperature range between -2 C…
The effect of the displacement damage on the Charge Collection Efficiency in Silicon Drift Detectors for the LOFT satellite
E. Del Monte, Y. Evangelista, E. Bozzo +7
The technology of Silicon Drift Detectors (SDDs) has been selected for the two instruments aboard the Large Observatory For X-ray Timing (LOFT) space mission. LOFT underwent a thre…
Radiation damage effects on detectors and eletronic devices in harsh radiation environment
S. Fiore
Radiation damage effects represent one of the limits for technologies to be used in harsh radiation environments as space, radiotherapy treatment, high-energy phisics colliders. Di…
Commissioning of the Inner Tracker of the KLOE-2 experiment
A. Di Cicco, G. Morello
The KLOE-2 experiment is undergoing commissioning at the DANE collider of the Frascati National Laboratory of the INFN, after the integration of new detectors in th…
Commissioning of the new taggers of the KLOE-2 experiment
D. Babusci, P. Ciambrone, M. Mascolo +4
In order to fully reconstruct the gamma gamma processes (e+e- -> e+e- gamma gamma) in the energy region of the phi meson production, new detectors along the DAFNE beam line have be…