papers

Publications (25)

astro-ph.CO2017

Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure

LUX Collaboration, D. S. Akerib, S. Alsum +97

We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg-year exposure acquired by the Large Underground Xenon experime…

hep-ex2016

Results on the Spin-Dependent Scattering of Weakly Interacting Massive Particles on Nucleons from the Run 3 Data of the LUX Experiment

LUX Collaboration, D. S. Akerib, H. M. Araújo +99

We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection ch…

astro-ph.IM2013

Technical Results from the Surface Run of the LUX Dark Matter Experiment

LUX Collaboration, D. S. Akerib, X. Bai +64

We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lea…

physics.ins-det2018

Position Reconstruction in LUX

LUX Collaboration, D. S. Akerib, S. Alsum +91

The position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a…

physics.ins-det2013

An Ultra-Low Background PMT for Liquid Xenon Detectors

D. S. Akerib, X. Bai, E. Bernard +64

Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diam…

astro-ph.CO2014

First results from the LUX dark matter experiment at the Sanford Underground Research Facility

LUX Collaboration, D. S. Akerib, H. M. Araujo +100

The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and…

physics.ins-det2017

Ultra-Low Energy Calibration of LUX Detector using Xe Electron Capture

LUX Collaboration, D. S. Akerib, S. Alsum +91

We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 3…

physics.ins-det2017

Chromatographic separation of radioactive noble gases from xenon

LUX Collaboration, D. S. Akerib, H. M. Araújo +96

The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Partic…

physics.ins-det2017

Calibration, event reconstruction, data analysis and limits calculation for the LUX dark matter experiment

D. S. Akerib, S. Alsum, H. M. Araújo +95

The LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sectio…

physics.ins-det2016

Tritium calibration of the LUX dark matter experiment

LUX Collaboration, D. S. Akerib, H. M. Araújo +98

We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the…

astro-ph.IM2011

After LUX: The LZ Program

D. C. Malling, D. S. Akerib, H. M. Araujo +71

The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 to…

physics.ins-det2017

3D Modeling of Electric Fields in the LUX Detector

LUX Collaboration, D. S. Akerib, S. Alsum +91

This work details the development of a three-dimensional (3D) electric field model for the LUX detector. The detector took data during two periods of searching for weakly interacti…

astro-ph.CO2017

Results from a search for dark matter in the complete LUX exposure

D. S. Akerib, S. Alsum, H. M. Araújo +98

We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experime…

astro-ph.IM2011

Data Acquisition and Readout System for the LUX Dark Matter Experiment

D. S. Akerib, X. Bai, S. Bedikian +60

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are pro…

physics.ins-det2012

The Large Underground Xenon (LUX) Experiment

D. S. Akerib, X. Bai, S. Bedikian +91

The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMP…

physics.data-an2011

LUXSim: A Component-Centric Approach to Low-Background Simulations

D. S. Akerib, X. Bai, S. Bedikian +60

Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been…

physics.ins-det2016

Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics

LUX Collaboration, D. S. Akerib, S. Alsum +104

The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota…

astro-ph.CO2016

Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data

LUX Collaboration, D. S. Akerib, H. M. Araújo +99

We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\ti…

physics.ins-det2016

FPGA-based Trigger System for the LUX Dark Matter Experiment

D. S. Akerib, H. M. Araujo, X. Bai +100

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector a…

nucl-ex2022

Direct measurement of the low energy resonances in reaction

S. Shahina, J. Gorres, D. Robertson +11

The is an important reaction in stellar helium burning environments as it competes directly with one of the main neutron sources for the s-process…

physics.ins-det2016

Signal yields, energy resolution, and recombination fluctuations in liquid xenon

D. S. Akerib, S. Alsum, H. M. Araújo +98

This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Undergrou…

physics.ins-det2012

Radio-assay of Titanium samples for the LUX Experiment

D. S. Akerib, X. Bai, S. Bedikian +63

We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construct…

physics.ins-det2017

Kr calibration of the 2013 LUX dark matter search

LUX Collaboration, D. S. Akerib, S. Alsum +91

LUX was the first dark matter experiment to use a Kr calibration source. In this paper we describe the source preparation and injection. We also present several $^…

astro-ph.CO2019

Extending light WIMP searches to single scintillation photons in LUX

D. S. Akerib, S. Alsum, H. M. Araújo +122

We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting…

astro-ph.CO2017

First Searches for Axions and Axion-Like Particles with the LUX Experiment

D. S. Akerib, S. Alsum, C. Aquino +98

The first searches for axions and axion-like particles with the Large Underground Xenon (LUX) experiment are presented. Under the assumption of an axio-electric interaction in xeno…