papers

Publications (14)

physics.ins-det2013

Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy -rays

The NEXT collaboration, V. Alvarez, F. I. G. M. Borges +87

NEXT-MM is a general-purpose high pressure (10 bar, l active volume) Xenon-based TPC, read out in charge mode with an 8 cm 8 cm-segmented 700 cm plane (1152 ch…

physics.ins-det2013

Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture

NEXT Collaboration, V. Álvarez, F. Aznar +82

A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~35 cm drift 28 cm diameter, it constitutes the larg…

physics.ins-det2015

Lessons from the operation of the "Penning-Fluorescent" TPC and prospects

Diego Gonzalez-Diaz, F. Aznar, J. Castel +15

We have recently reported the development of a new type of high-pressure Xenon time projection chamber operated with an ultra-low diffusion mixture and that simultaneously displays…

physics.ins-det2015

TREX-DM: a low background Micromegas-based TPC for low mass WIMP detection

F. J. Iguaz, J. G. Garza, F. Aznar +11

Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we p…

physics.ins-det2016

The potential of discrimination methods in a high pressure xenon TPC for the search of the neutrinoless double-beta decay of Xe-136

F. J. Iguaz, F. Aznar, J. F. Castel +8

In the search for the neutrinoless double beta decay of Xe, a high pressure xenon time projection chamber (HPXe-TPC) has two advantages over liquid xenon TPCs: a better ene…

physics.ins-det2013

X-ray detection with Micromegas with background levels below 10 keVcms

S. Aune, F. Aznar, D. Calvet +26

Micromegas detectors are an optimum technological choice for the detection of low energy x-rays. The low background techniques applied to these detectors yielded remarkable backgro…

physics.ins-det2015

Gaseous time projection chambers for rare event detection: Results from the T-REX project. I. Double beta decay

I. G. Irastorza, F. Aznar, J. Castel +13

As part of the T-REX project, a number of R&D and prototyping activities have been carried out during the last years to explore the applicability of gaseous Micromegas-read TPCs in…

physics.ins-det2015

A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research

F. Aznar, J. Castel, F. E. Christensen +18

We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbu…

astro-ph.IM2015

Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches

F. J. Iguaz, S. Aune, F. Aznar +14

Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component…

physics.ins-det2016

Gaseous time projection chambers for rare event detection: Results from the T-REX project. II. Dark matter

I. G. Irastorza, F. Aznar, J. Castel +13

As part of the T-REX project, a number of R&D and prototyping activities have been carried out during the last years to explore the applicability of Micromegas-read gaseous TPCs in…

physics.ins-det2016

TREX-DM: a low background Micromegas-based TPC for low-mass WIMP detection

F. J. Iguaz, J. G. Garza, F. Aznar +8

Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we d…

physics.ins-det2016

TREX-DM: a low-background Micromegas-based TPC for low-mass WIMP detection

F. J. Iguaz, J. G. Garza, F. Aznar +8

If Dark Matter is made of Weakly Interacting Massive Particles (WIMPs) with masses below 20 GeV, the corresponding nuclear recoils in mainstream WIMP experiments are of energ…

physics.ins-det2015

Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres

Diego Gonzalez-Diaz, V. Alvarez, F. I. G. Borges +80

We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with t…

physics.ins-det2015

Comissioning of TREX-DM, a low background Micromegas-based Time Projection Chamber for low mass WIMP detection

F. J. Iguaz, J. G. Garza, F. Aznar +8

Dark Matter experiments are recently focusing their detection techniques in low-mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we d…