paper

Probing Internal Conversion and Dark-Matter-Induced De-excitation of 180mTa with a gamma-ray TES Array

arXiv:2512.21468

Abstract

We propose and evaluate a source-as-detector search for the de-excitation of the long-lived isomer in natural tantalum (Ta), using a -ray transition-edge-sensor (TES) array. We exploit two capabilities not available in conventional high-purity germanium (HPGe) searches: (i) near-unity containment of low-energy secondaries (internal-conversion electrons and characteristic X rays), as well as the nuclear recoil, enabling a calorimetric, event-by-event measurement of the total energy deposited in the absorber; and (ii) a delayed-coincidence tag based on the subsequent Ta electron-capture (EC) decay to Hf. We evaluate the discovery reach for internal conversion (IC) and for dark-matter-induced de-excitation in two benchmark scenarios: a strongly interacting dark-matter (DM) subcomponent and inelastic DM with off-diagonal couplings. Using a background model based on intrinsic radioactivity in the Ta absorber and realistic detector performance, we show that arrays with and pixels can reach the theoretically expected IC half-life within yr and yr, respectively. For an array with and a five-year exposure, the projected sensitivity to DM-induced de-excitation surpasses limits inferred from HPGe non-observations of Ta and probes regions of parameter space not covered by current direct-detection experiments.

16 pages, 6 figures. Accepted for publication in Phys. Rev. D