Functional Verification for Endcap Concentrator ASICs in the High-Granularity Calorimeter Upgrade of CMS
arXiv:2411.03476 · doi:10.1088/1748-0221/20/02/C02004
Abstract
The High-Granularity Calorimeter (HGCAL) will replace the current CMS Endcap Calorimeter during Long-Shutdown 3. The Endcap Concentrator (ECON) ASICs represent key elements in the readout chain, processing trigger (ECON-T) and data (ECON-D) streams from the HGCROC to the lpGBT. The ECONs will operate in a radiation environment with a High-Energy Hadron () flux up to . This contribution describes the Universal Verification Methodology (UVM)-based functional verification of the ECON ASICs focusing on the re-use of existing components to manage the complexity of the verification environment.
- TWEPP 2024 proceeding - 5 pages + title page, 2 figures