Test of a Liquid Argon TPC in a magnetic field and investigation of high temperature superconductors in liquid argon and nitrogen

arXiv:1010.5811 · doi:10.1088/1742-6596/308/1/012026

Abstract

Tests with cosmic ray muons of a small liquid argon time projection chamber (LAr TPC) in a magnetic field of 0.55 T are described. No effect of the magnetic field on the imaging properties were observed. In view of a future large, magnetized LAr TPC, we investigated the possibility to operate a high temperature superconducting (HTS) solenoid directly in the LAr of the detector. The critical current of HTS cables in an external magnetic field was measured at liquid nitrogen and liquid argon temperatures and a small prototype HTS solenoid was built and tested.

5 pages, 5 figures, to appear in Proc. of 1st International Workshop towards the Giant Liquid Argon Charge Imaging Experiment (GLA2010), Tsukuba (Japan), March 2010