papers

Publications (9)

physics.ins-det2014

Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

D. Abbaneo, M. Abbas, M. Abbrescia +134

Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for…

physics.ins-det2013

Study of gas contaminants and interaction with materials in RPC closed loop system

S. Colafranceschi, R. Aurilio, L. Benussi +18

Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this pape…

physics.ins-det2015

Candidate eco-friendly gas mixtures for MPGDs

L. Benussi, S. Bianco, G. Saviano +13

Modern gas detectors for detection of particles require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be l…

physics.ins-det2016

Eco-friendly gas mixtures for Resistive Plate Chambers based on Tetrafluoropropene and Helium

M. Abbrescia, L. Benussi, S. Bianco +8

Due to the recent restrictions deriving from the application of the Kyoto protocol, the main components of the gas mixtures presently used in the Resistive Plate Chambers systems o…

physics.ins-det2012

A study of gas contaminants and interaction with materials in RPC closed loop systems

S. Colafranceschi, R. Aurilio, L. Benussi +18

Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this pape…

physics.ins-det2015

Characterization of the GEM foil materials

L. Benussi, S. Bianco, G. Saviano +19

Systematic studies on the GEM foil material are performed to measure the moisture diffusion rate and saturation level. These studies are important because the presence of this comp…

physics.ins-det2016

Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

M. Abbrescia, P. Van Auwegem, L. Benussi +11

The operations of Resistive Plate Chambers in LHC experiments require Fluorine based (F-based) gases for optimal performance. Recent European regulations demand the use of environm…

physics.ins-det2015

A study of HFO-1234ze (1,3,3,3-Tetrafluoropropene) as an eco-friendly replacement in RPC detectors

L. Benussi, S. Bianco, M. Ferrini +5

The operations of Resistive Plate Chambers in LHC experiments require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based…

physics.ins-det2010

Study of gas purifiers for the CMS RPC detector

L. Benussi, S. Bianco, S. Colafranceschi +26

The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has b…